Image of ANALISIS GANGGUAN SISTEM TRANSMISI MENGGUNAKAN ALAT DIGITAL FAULT RECORDER DAN MENENTUKAN TITIK LOKASI GANGGUAN MELALUI PERBANDINGAN ALAT PELACAK BERBASIS TRAVELLING WAVE SYSTEM

Skripsi

ANALISIS GANGGUAN SISTEM TRANSMISI MENGGUNAKAN ALAT DIGITAL FAULT RECORDER DAN MENENTUKAN TITIK LOKASI GANGGUAN MELALUI PERBANDINGAN ALAT PELACAK BERBASIS TRAVELLING WAVE SYSTEM

Saputra, Canra Andi - Personal Name;

Penilaian

0,0

dari 5
Penilaian anda saat ini :  

DFR (Digital Fault Recorder) and TWS (Traveling Wave System) equipment which functions to record and store the data system condition automatically before, at the time of the disturbance and at the time after the disturbance, both in the form of disturbance type data and disturbance distance. This study uses the results of the recorded data on the DFR equipment which will be analyzed with the results of determining the characteristics of the disturbance that occurs by using the fault signature method and determining the location of the disturbance with the recorded data then it will be compared with the results of the recording on the TWS equipment. During the analysis process, the reseacher looked at the notes in the form of I Faul) and V Fault for each disturbance with data obtained within a period of 8 months starting from January 14 to August 12 2020. Furthermore, I Fault and V Fault will be taken as input in formula processing. With the result obtained that there were 8 disturbance caused by lightning, 1 disturbance caused by tree/ground, and 1 disturbance caused by dirty isolator and difference between the two rasio ± 0,5 KM with between difference 0,07 – 0,5 KM. The result obtained that there were from 6 disturbance immediately checked in the field have 4 disturbance approaching from manual calculation used record file DFR Equipment and 2 other disturbance approaching with record file from TWS equipment. So in terms of accuracy and optimalization, manual calculation very effective for used.


Availability
Inventory Code Barcode Call Number Location Status
2007001414T39864T398642020Central Library (REFERENCES)Available but not for loan - Not for Loan
Detail Information
Series Title
-
Call Number
T398642020
Publisher
Inderalaya : Jurusan Teknik Elektro, Fakultas Teknik Universitas Sriwijaya., 2020
Collation
xvii, 107 hlm. : ilus. ; 28 cm
Language
Indonesia
ISBN/ISSN
-
Classification
621.319 07
Content Type
Text
Media Type
unmediated
Carrier Type
-
Edition
-
Subject(s)
sistem transmisi
Jurusan Teknik Elektro
Specific Detail Info
-
Statement of Responsibility
DS
Other version/related

No other version available

File Attachment
  • ANALISIS GANGGUAN SISTEM TRANSMISI MENGGUNAKAN ALAT DIGITAL FAULT RECORDER DAN MENENTUKAN TITIK LOKASI GANGGUAN MELALUI PERBANDINGAN ALAT PELACAK BERBASIS TRAVELLING WAVE SYSTEM
Comments

You must be logged in to post a comment

The Sriwijaya University Library
  • Information
  • Services
  • Librarian
  • Member Area

About Us

As a complete Library Management System, SLiMS (Senayan Library Management System) has many features that will help libraries and librarians to do their job easily and quickly. Follow this link to show some features provided by SLiMS.

Search

start it by typing one or more keywords for title, author or subject

Keep SLiMS Alive Want to Contribute?

© 2025 — Senayan Developer Community

Powered by SLiMS
Select the topic you are interested in
  • Computer Science, Information & General Works
  • Philosophy & Psychology
  • Religion
  • Social Sciences
  • Language
  • Pure Science
  • Applied Sciences
  • Art & Recreation
  • Literature
  • History & Geography
Icons made by Freepik from www.flaticon.com
Advanced Search