Image of SIMULASI TEGANGAN KONTAK PADA IMPLAN PINGGUL KERAMIK-KERAMIK DENGAN PERBEDAAN JARAK RADIAL

Skripsi

SIMULASI TEGANGAN KONTAK PADA IMPLAN PINGGUL KERAMIK-KERAMIK DENGAN PERBEDAAN JARAK RADIAL

Putra, Revata Jaya - Personal Name;

Penilaian

0,0

dari 5
Penilaian anda saat ini :  

This study aims to evaluate the effect of variations in radial clearance on the contact mechanics characteristics and temperature due to friction in zirconia (ZrO₂-ZrO₂) ceramic hip joint implants. Radial clearance is an important geometric parameter that directly influences lubrication efficiency, pressure distribution, and wear rate. Improper clearance values can lead to increased friction over time. Therefore, this study was conducted numerically using the finite element method (FEM) in ABAQUS/CAE software, varying the radial clearance from 0.03 mm to 0.3 mm. The simulation model includes symmetric geometry between the femoral head and acetabular cup, subjected to normal walking load over a full gait cycle. Analyzed parameters include maximum contact pressure, deformation distribution, von Mises and Tresca stresses, as well as temperature generated by friction between bearing surfaces. Simulation results show that increasing radial clearance causes an increase in contact pressure and surface deformation, resulting in higher internal stresses and greater risk of material failure. The highest von Mises and Tresca stresses were observed at a clearance of 0.3 mm, approaching the yield limit of ZrO₂ material. Furthermore, the temperature distribution due to friction indicates a significant temperature rise at the largest clearance, which could potentially damage the biological tissue surrounding the implant. Conversely, excessively small clearance reduces pressure and temperature but risks lowering lubrication efficiency and increasing localized wear. Based on these results, it can be concluded that selecting an appropriate radial clearance is a key factor in the design of ceramic hip implants. This study provides an important foundation for the development of durable and biomechanically and safe implant designs.


Availability
Inventory Code Barcode Call Number Location Status
2507003450T175875T1758752025Central Library (Reference)Available but not for loan - Not for Loan
Detail Information
Series Title
-
Call Number
T1758752025
Publisher
Indralaya : Prodi Teknik Mesin, Fakultas Teknik Universitas Sriwijaya., 2025
Collation
xxxv, 128 hlm.; ilus.; tab.; 29 cm.
Language
Indonesia
ISBN/ISSN
-
Classification
621.807
Content Type
Text
Media Type
-
Carrier Type
-
Edition
-
Subject(s)
Teknik mesin
Specific Detail Info
-
Statement of Responsibility
MI
Other version/related

No other version available

File Attachment
  • SIMULASI TEGANGAN KONTAK PADA IMPLAN PINGGUL KERAMIK-KERAMIK DENGAN PERBEDAAN JARAK RADIAL
Comments

You must be logged in to post a comment

The Sriwijaya University Library
  • Information
  • Services
  • Librarian
  • Member Area

About Us

As a complete Library Management System, SLiMS (Senayan Library Management System) has many features that will help libraries and librarians to do their job easily and quickly. Follow this link to show some features provided by SLiMS.

Search

start it by typing one or more keywords for title, author or subject

Keep SLiMS Alive Want to Contribute?

© 2025 — Senayan Developer Community

Powered by SLiMS
Select the topic you are interested in
  • Computer Science, Information & General Works
  • Philosophy & Psychology
  • Religion
  • Social Sciences
  • Language
  • Pure Science
  • Applied Sciences
  • Art & Recreation
  • Literature
  • History & Geography
Icons made by Freepik from www.flaticon.com
Advanced Search