ANALISIS ENERGI DAN EKSERGI PADA SISTEM PEMBANGKIT LISTRIK TENAGA UAP (PLTU) PT. TANJUNG ENIM LESTARI PULP AND PAPER
This paper presents exergy and energy analysis of steam power plant system at PT. Tanjung Enim Lestari Pulp and Paper (PT.Telpp) that aims to improve performance by analyze the components and the overall system. Energy analysis is able to know location, type and losses that occur during the process. Energy rate, exergy, energy and exergy efficiency and irreversibility is calculated based on the operating data of PT. Telpp. The steam power plant that studied is power plant by using extraction turbine with output power is 47,7 MW. Based on the research that has been done, condensate tank has the lowest of exergy efficiency is equal to 17,3054 %>, meanwhile second condensate pump is component with the highest exergy efficiency of 76,3126 %. Deaerator is component with the highest energy efficiency of 99,3562 %>,meanwhile power boiler is component with the lowest energy efficiency of29,7757 %. The greatest Irreversibility occurs in the recovery boiler, that is equal to 163.0488 MW, meanwhile the lowest irreversibility occurs in first condensate pump, that is equal to 0,00231 M W.