Skripsi
ANALISA EFEK KONFIGURASI KOIL PEMANAS TERHADAP TEMPERATUR DAN DISTRIBUSI ALIRAN UDARA DIDALAM PENGERING KAYU JENIS KOMPARTEMEN MENGGUNAKAN CFD
Problem that exists in the timber industry in particularly process of reducing water content in the wood using compartment kiln is heating coil configuration wilhin the kiln. In this research, the coil installation will be determined the best of coil installations by taking samples from the factories by looking at the heat and airflow distribution uniformity within the kiln. Method of This study is CFD (Computational Fluid Dynamic) analysis by Software Flovent 9. J. There are 3 variables of coil configuration, the coil placed horizontally (parallel to the fluid flow of the fan), vertically (perpendicular to the fluid flow), and with slope of 57°. This research concluded that the position of the coils have uniform distribution ofheat and air flow is in the horizontal position or parallel to the direction of air flow. Coil installation vertically has a good uniformity of air flow distribution and with highest efficiency of thermal.
Inventory Code | Barcode | Call Number | Location | Status |
---|---|---|---|---|
1407000816 | T158934 | T1589342014 | Central Library (Reference) | Available but not for loan - Not for Loan |
No other version available