Skripsi
IDENTIFIKASI KEBERADAAN AIR TANAH MENGGUNAKAN METODE RESISTIVITAS KONFIGURASI SCHLUMBERGER DI LOKASI KEBUN X DESA TAJA RAYA II KECAMATAN BETUNG KABUPATEN BANYUASIN PROVINSI SUMATERA SELATAN
Desa Taja Raya II terletak di Kecamatan Betung Kabupaten Banyuasin Provinsi Sumatera Selatan. Tujuan dilakukannya penelitian ini yaitu untuk menenetuan keberadaan air tanah serta menentukan rekomendasi titik bor. Penenlitian ini dilakukan dengan menggunakan metode geolistrik resistivitas 1 dimensi konfigurasi sclumberger dengan jarak elektroda 8 meter. Pengukuran di lapangan di ukur titik 15 titik sounding panjang lintasan 160 meter dengan jaral spasi antar elektroda 8 meter. Hasil Pengukuran geolistrik resistivitas yang didapatkan diolah menggunakan IPI2win guna untuk mengeetahui jumlah lapisan batuan, lalu data tersebut diolah menggunakan surfer untuk menentukan rekomendasi titik bor. Berdasarkan hasil intepretasi data dan analisa didapatkan bahwa pada lokasi penelitian memiliki air tanah dengan melihat nilai rho yang terendah dan pada nilai resistivitas 120 – 320 Ωm. Rekomendasi posisi titik bor air tanah didapatkan pada titik koordinat X : 416315 dan Y : 9680803. Kata kunci : Metode Geolistrik Resistivitas, Konfigurasi Schlumberger, Air Tanah, IPI2win, Surfer Taja Raya II Village is located in Betung District, Banyuasin Regency, South Sumatra Province. The aim of this research is to determine the presence of groundwater and determine recommended drill points. This research was carried out using the sclumberger configuration 1-dimensional resistivity geoelectric method with an electrode distance of 8 meters. Measurements in the field were measured at 15 sounding points with a path length of 160 meters with a distance between electrodes of 8 meters. The results of the geoelectric resistivity measurements obtained were processed using IPI2win to determine the number of rock layers, then the data was processed using surfer to determine recommended drill points. Based on the results of data interpretation and analysis, it was found that the research location had groundwater by looking at the lowest rho value and a resistivity value of 120 – 320 Ωm. The recommended position for groundwater drilling points is obtained at coordinates X: 416315 and Y: 9680803. Keywords: Geoelectric Resistivity Method, Schlumberger Configuration, Ground Water, IPI2win, Surfer
Inventory Code | Barcode | Call Number | Location | Status |
---|---|---|---|---|
2407001454 | T140556 | T1405562024 | Central Library (References) | Available but not for loan - Not for Loan |
No other version available