The Sriwijaya University Library

  • Home
  • Information
  • News
  • Help
  • Librarian
  • Login
  • Member Area
  • Select Language :
    Arabic Bengali Brazilian Portuguese English Espanol German Indonesian Japanese Malay Persian Russian Thai Turkish Urdu

Search by :

ALL Author Subject ISBN/ISSN Advanced Search

Last search:

{{tmpObj[k].text}}
Image of PENGARUH PAPARAN ASAM FORMAT (CH2O2) TERHADAP PELUAHAN AWAL PEMOHONAN LISTRIK PADA ISOLASI EPOXY RESIN. 

Skripsi

PENGARUH PAPARAN ASAM FORMAT (CH2O2) TERHADAP PELUAHAN AWAL PEMOHONAN LISTRIK PADA ISOLASI EPOXY RESIN. 

Putri, Nadia Sagita  - Personal Name;

Penilaian

0,0

dari 5
Penilaian anda saat ini :  

This study discusses the electrical treeing phenomenon that occurs in epoxy resin insulation material by formic acid (CH2O2) with variations conditioning time ranging 12; 24; and 48 hours. Epoxy resin without conditioning as a control using a leaf-like sample electrode system. The tests carried out are measurements of treeing inception voltage, treeing shape, treeing length, and accumulation damage. After tree initiated, the voltage will be increased to 0,2; 0,4; and 0,6 kV to observe its influence to electrical treeing growth. The highest value of inception voltage is found in the epoxy resin without conditioning that which is 5,05 kV and the lowest value of inception voltage is found in the epoxy resin with conditioning for 48 hours that is 3,60 kV. The highest value of tree length is found in epoxy resin conditioning for 48 hours with +0,2 kV; +0,4kV; and +0,6 kV addition voltage consecutively equal to 327,765 μm, 437,478 μm, and 585,48 μm. While the lowest value of tree length is found in epoxy resin without conditioning with +0,2 kV; +0,4kV; and +0,6 kV addition voltage consecutively equal to 279,96 μm, 299,57 μm, saat 341,77 μm. The lowest value of accumulated damage for +0,2 kV addition voltage is found in epoxy resin without conditioning that equals to 1,9082 x 103 pixels, while the highest value of accumulated damage value was for +0,6 kV addition voltage are found in epoxy resin for 48 hours that equals to 15,4422 x 103 pixels


Availability
Inventory Code Barcode Call Number Location Status
2307004039T126985T1269852023Central Library (Referens)Available
Detail Information
Series Title
-
Call Number
T1269852023
Publisher
Indralaya : Prodi Teknik Elektro, Fakultas Teknik Universitas Sriwijaya ;., 2023
Collation
xxi, 50 hlm.; ilus.; 21 cm
Language
Indonesia
ISBN/ISSN
-
Classification
621.316 07
Content Type
Text
Media Type
unmediated
Carrier Type
-
Edition
-
Subject(s)
Prodi Teknik Elektro
Alat-alat Kontrol Listrik- Peluahan
Specific Detail Info
-
Statement of Responsibility
MURZ
Other version/related

No other version available

File Attachment
  • PENGARUH PAPARAN ASAM FORMAT (CH2O2) TERHADAP PELUAHAN AWAL PEMOHONAN LISTRIK PADA ISOLASI EPOXY RESIN. 
Comments

You must be logged in to post a comment

The Sriwijaya University Library
  • Information
  • Services
  • Librarian
  • Member Area

About Us

As a complete Library Management System, SLiMS (Senayan Library Management System) has many features that will help libraries and librarians to do their job easily and quickly. Follow this link to show some features provided by SLiMS.

Search

start it by typing one or more keywords for title, author or subject

Keep SLiMS Alive Want to Contribute?

© 2025 — Senayan Developer Community

Powered by SLiMS
Select the topic you are interested in
  • Computer Science, Information & General Works
  • Philosophy & Psychology
  • Religion
  • Social Sciences
  • Language
  • Pure Science
  • Applied Sciences
  • Art & Recreation
  • Literature
  • History & Geography
Icons made by Freepik from www.flaticon.com
Advanced Search