Image of ANALISIS PENGARUH DIAMETER KAWAT KUMPARAN PADA MESIN STERILISASI ALAT MEDIS PORTABEL

Skripsi

ANALISIS PENGARUH DIAMETER KAWAT KUMPARAN PADA MESIN STERILISASI ALAT MEDIS PORTABEL

Hanafi, Akmal Syukri - Personal Name;

Penilaian

0,0

dari 5
Penilaian anda saat ini :  

Every hospital activity must meet agreed medical standards, including sterilization of the use of medical devices. With the dry heat sterilization method in the oven, a sterilization machine is needed that can be easily carried in a portable form. The use of wire coils as heat conductors is needed to make sterilization machines, where the larger the diameter of the coil can reduce the power used and the smaller the diameter of the coil can accelerate temperature changes in the coil. This research was carried out by assembling a sterilization machine with various components needed so that measurements can be made of voltage, current, time to reach sterile temperatures and calculation of the power produced. In making portable medical device sterilizers, the use of coil wires with diameters of 0.8 mm, 1 mm, 1.2 mm, and 1.3 mm has been tested as a trigger for hot temperatures in machines where the coil wire with a diameter of 0.8 mm is able to provide the best results than other coil wire diameters. Of the four variations in coil wire diameter, coil wire with a diameter of 0.8 mm produces a maximum value with a voltage of 56.2 volts, an electric current of 4.08 Amperes, and the fastest heating time of 18.51 minutes. This is appropriate based on the relationship between diameter and resistance where the smaller the diameter, the greater the resistance value in a circuit which can affect the value of current and voltage flowing. The largest power value comes from a 0.8 mm diameter coil wire rated at 114.64 Watts. This is based on the correlation between the power value, the voltage and current value, that is, the greater the current value, the greater the power value produced. The smallest power value comes from a coil wire with a diameter of 1.3 mm valued at 19.31 Watts.


Availability
Inventory Code Barcode Call Number Location Status
2307001872T104508T1045082023Central Library (Referens)Available
Detail Information
Series Title
-
Call Number
T1045082023
Publisher
Indralaya : Prodi Teknik Elektro, Fakultas Teknik Universitas Sriwijaya ;., 2023
Collation
xiii, 35 hlm.; ilus.; 29 cm
Language
Indonesia
ISBN/ISSN
-
Classification
621.370 7
Content Type
Text
Media Type
unmediated
Carrier Type
-
Edition
-
Subject(s)
Pengujian dan Pengukuran Listrik
Prodi Teknik Elektro
Specific Detail Info
-
Statement of Responsibility
MURZ
Other version/related

No other version available

File Attachment
  • ANALISIS PENGARUH DIAMETER KAWAT KUMPARAN PADA MESIN STERILISASI ALAT MEDIS PORTABEL
Comments

You must be logged in to post a comment

The Sriwijaya University Library
  • Information
  • Services
  • Librarian
  • Member Area

About Us

As a complete Library Management System, SLiMS (Senayan Library Management System) has many features that will help libraries and librarians to do their job easily and quickly. Follow this link to show some features provided by SLiMS.

Search

start it by typing one or more keywords for title, author or subject

Keep SLiMS Alive Want to Contribute?

© 2025 — Senayan Developer Community

Powered by SLiMS
Select the topic you are interested in
  • Computer Science, Information & General Works
  • Philosophy & Psychology
  • Religion
  • Social Sciences
  • Language
  • Pure Science
  • Applied Sciences
  • Art & Recreation
  • Literature
  • History & Geography
Icons made by Freepik from www.flaticon.com
Advanced Search