The Sriwijaya University Library

  • Home
  • Information
  • News
  • Help
  • Librarian
  • Login
  • Member Area
  • Select Language :
    Arabic Bengali Brazilian Portuguese English Espanol German Indonesian Japanese Malay Persian Russian Thai Turkish Urdu

Search by :

ALL Author Subject ISBN/ISSN Advanced Search

Last search:

{{tmpObj[k].text}}
Image of PERBANDINGAN METODE SPEKTROFOTOMETRI VISIBLE DAN POTENSIOMETRI TERHADAP ANALISIS LOGAM BESI PADA AIR SUNGAI LEMATANG

Skripsi

PERBANDINGAN METODE SPEKTROFOTOMETRI VISIBLE DAN POTENSIOMETRI TERHADAP ANALISIS LOGAM BESI PADA AIR SUNGAI LEMATANG

Rahmaputri, Kartika Sophia Nurcahyani - Personal Name;

Penilaian

0,0

dari 5
Penilaian anda saat ini :  

This research compares the methods of iron metal analysis Fe2+ ions using visible spectroscopy and concentration cell potentiometry. The visible spectroscopy method needs to be verified, and the potentiometry method needs to be validated based on ISO 17025:2017, with parameters of linearity, sensitivity, detection limit, quantification limit, accuracy, precision, and measurement uncertainty. The analysis of iron metal using visible spectroscopy is carried out by reducing Fe3+ to Fe2+ and then complexing it with o phenanthroline to form the iron (II) phenanthroline complex. The analysis of iron metal using potentiometry is based on concentration cell, by measuring the potential of Fe3+ solution that has been reduced to Fe2+. Both methods are then applied to measure the iron metal in the Lematang River water. The results of the standard series measurement produced a calibration curve with a linear equation for visible spectrophotometry y = 0.02526x + 0.00004, and for potentiometry concentration cell y = 1.012x+1.122 with R2 values of 0.9986 and 0.9985. The sensitivity values are 0.02526 and 1.012, the detection limits are 0.1916 mg/L and 0.2425 mg/L, and the quantification limits are 0.4774 mg/L and 0.2747 mg/L. The precision values are 4.11% and 7.93%, while the accuracy values are 95.012% and 80.8%. The measurement uncertainty values are ± 0.044 mg/L and ± 0.787 mg/L. The Fe sample in the Lematang River water is (0.894 ± 0.044) mg/L and (1.066 ± 0.787) mg/L. The t-test value of 1.253 and the t-table value of 2.78 (α = 95%) indicate that both methods are not significantly different in analyzing Fe2+ ions.


Availability
Inventory Code Barcode Call Number Location Status
2307003378T105736T1057362023Central Library (Referens)Available
Detail Information
Series Title
-
Call Number
T1057362023
Publisher
Indralaya : Jurusan Kimia, Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Sriwijaya., 2023
Collation
xvii, 80 hlm.; Ilus.; 21 cm
Language
Indonesia
ISBN/ISSN
-
Classification
546.307
Content Type
-
Media Type
-
Carrier Type
-
Edition
-
Subject(s)
Jurusan Kimia
Logam Besi
Specific Detail Info
-
Statement of Responsibility
PITRIA
Other version/related

No other version available

File Attachment
  • PERBANDINGAN METODE SPEKTROFOTOMETRI VISIBLE DAN POTENSIOMETRI TERHADAP ANALISIS LOGAM BESI PADA AIR SUNGAI LEMATANG
Comments

You must be logged in to post a comment

The Sriwijaya University Library
  • Information
  • Services
  • Librarian
  • Member Area

About Us

As a complete Library Management System, SLiMS (Senayan Library Management System) has many features that will help libraries and librarians to do their job easily and quickly. Follow this link to show some features provided by SLiMS.

Search

start it by typing one or more keywords for title, author or subject

Keep SLiMS Alive Want to Contribute?

© 2025 — Senayan Developer Community

Powered by SLiMS
Select the topic you are interested in
  • Computer Science, Information & General Works
  • Philosophy & Psychology
  • Religion
  • Social Sciences
  • Language
  • Pure Science
  • Applied Sciences
  • Art & Recreation
  • Literature
  • History & Geography
Icons made by Freepik from www.flaticon.com
Advanced Search