Text
ANALISA PENGARUH MUATAN HIDRAULIKA TERHADAP KINERJA CONSTRUCTED WETLAND PADA PENGOLAHAN LIMBAH KARET
Utilization of an environmentally sound drainage system or eco-drainage is a drainage management system in a sustainable manner by observing the carrying capacity of nature or environmental conditions so that solutions to problems caused by runoff of rainwater and wastewater can be created and can reduce the pollutant parameters of water that enters the final disposal. The initial condition of the rubber waste water before processing is that it contains an initial concentration of 3,138 Mg/L for BOD5, COD of 1,602 Mg/L, TSS of 795 Mg/L, and a pH of 4.5. At a retention time of 72 hours the constructed wetland reduces pollutant levels to meet the rubber waste water quality standards set by the government as stated in the Minister of Environment Regulation no. 5 of 2014. Based on the calculations for the planning of the Mulya Guna Village rubber plantation wastewater treatment plant using the constructed wetland system, the dimensions for 2 equalization tanks (reservoir tanks) are 168 cm x 70 cm x 70 cm and the dimensions for the constructed wetland reactor of 201 cm x 70 cm x 50 cm to accommodate a volume of water of 390 liters
Inventory Code | Barcode | Call Number | Location | Status |
---|---|---|---|---|
2307001319 | T91223 | T912232023 | Central Library (Referens) | Available but not for loan - Not for Loan |
No other version available