Image of ANALISA GANGGUAN HUBUNG SINGKAT SATU FASA KE TANAH MENGGUNAKAN SETTING GROUND FAULT RELAY (GFR) PADA TRANSFORMATOR 30 MVA DI GARDU INDUK BOOM BARU

Text

ANALISA GANGGUAN HUBUNG SINGKAT SATU FASA KE TANAH MENGGUNAKAN SETTING GROUND FAULT RELAY (GFR) PADA TRANSFORMATOR 30 MVA DI GARDU INDUK BOOM BARU

Kamilah, Raidah Sabrina - Personal Name;

Penilaian

0,0

dari 5
Penilaian anda saat ini :  

At present the community's need for electrical energy consumption increases from year to year at the Boom Baru Substation, so that the electric power system must be able to guarantee in terms of availability and quality of service. One form of transformer disturbance that often occurs in substations is NGR. Neutral Grounding Resistor (NGR) which is one of the grounding systems that functions as a current limiter or minimizes fault currents, especially single-phase short-circuit faults to ground. The NGR also sends a signal through the current transformer to the Ground Fault Relay (GFR) which functions to break the circuit breaker if the fault current exceeds that obtained by the transformer. Therefore, it is necessary to re-calculate to determine the condition and readiness of safety equipment to maintain the reliability of the electric power system. Therefore the author performs a one-phase-to-ground short circuit fault analysis using the Ground Fault Relay (GFR) setting on a 30 MVA transformer at the Boom Baru Substation by using short circuit fault analysis calculations and also calculating ground fault relay settings. The calculation results obtained on the value of the single-phase short-circuit current to ground using R = 40 ꭥ at a location with a fault of 25% at the date feeder is 277.2337 A. while the short-circuit current value of one-phase to ground with solid grounding at the location of the fault of 25% on date feeders is 579.4504 A. so using NGR is much better than solid grounding. From the results of calculating the GFR setting using the Standard Inverse characteristic, the TMS value has the same magnitude for each feeder, which is equal to 0.1 SI.


Availability
Inventory Code Barcode Call Number Location Status
2307002558T116217T1162172023Central Library (Referens)Available but not for loan - Not for Loan
Detail Information
Series Title
-
Call Number
T1162172023
Publisher
Inderalaya : Prodi Teknik Elektro, Fakultas Teknik Universitas Sriwijaya., 2023
Collation
xiv, 53 hlm.; ilus.; 29 cm
Language
Indonesia
ISBN/ISSN
-
Classification
621.319 07
Content Type
-
Media Type
-
Carrier Type
-
Edition
-
Subject(s)
Transmisi dan distribusi listrik
Prodi Teknik Elektro
Specific Detail Info
-
Statement of Responsibility
SEPTA
Other version/related

No other version available

File Attachment
  • ANALISA GANGGUAN HUBUNG SINGKAT SATU FASA KE TANAH MENGGUNAKAN SETTING GROUND FAULT RELAY (GFR) PADA TRANSFORMATOR 30 MVA DI GARDU INDUK BOOM BARU
Comments

You must be logged in to post a comment

The Sriwijaya University Library
  • Information
  • Services
  • Librarian
  • Member Area

About Us

As a complete Library Management System, SLiMS (Senayan Library Management System) has many features that will help libraries and librarians to do their job easily and quickly. Follow this link to show some features provided by SLiMS.

Search

start it by typing one or more keywords for title, author or subject

Keep SLiMS Alive Want to Contribute?

© 2025 — Senayan Developer Community

Powered by SLiMS
Select the topic you are interested in
  • Computer Science, Information & General Works
  • Philosophy & Psychology
  • Religion
  • Social Sciences
  • Language
  • Pure Science
  • Applied Sciences
  • Art & Recreation
  • Literature
  • History & Geography
Icons made by Freepik from www.flaticon.com
Advanced Search