Skripsi
ANALISA ALIRAN DAYA PADA SISTEM TENAGA LISTRIK PT. PLN (PERSERO) UP2B SUB SISTEM SUMATERA SELATAN (70 KV) DENGAN METODE FAST DECOUPLE
The electric power system used in Indonesia is basically interconnected with each other. The interconnection system is an electric power system consisting of several electrical energy centers and substations which are connected through transmission lines and serve the existing loads on all substations. Distribution can also be called power flow. In this final project, Matrix Laboratory software is used to determine changes in active and reactive power using the Fast Decouple method. In this final project, a power flow analysis is carried out on a 70 kV system at PT. PLN (PERSERO) UP2B South Sumatra Sub-System. From the results of the Matrix Laboratory application simulation using the Fast Decouple method with calculations reaching convergence at the 18th iteration and the active and reactive power losses on the transmission line are 1.058 MW and 8.924 MVAR obtained from the results of the calculations that have been carried out. Calculation of power flow using the Matrix Laboratory application can be an alternative, although it has disadvantages such as coding that is easy to error and difficult to find out what mistakes have been made.
Inventory Code | Barcode | Call Number | Location | Status |
---|---|---|---|---|
2207004472 | T81603 | T816032022 | Central Library (Referens) | Available |
No other version available