Image of EVALUASI SISTEM PROTEKSI PETIR EKSTERNAL DAN PERHITUNGAN TEGANGAN SAAT SAMBAR PETIR PADA STASIUN PENYIMPANAN AVTUR PULAU LAYANG BERBASIS SOFTWARE ATP-DRAW

Skripsi

EVALUASI SISTEM PROTEKSI PETIR EKSTERNAL DAN PERHITUNGAN TEGANGAN SAAT SAMBAR PETIR PADA STASIUN PENYIMPANAN AVTUR PULAU LAYANG BERBASIS SOFTWARE ATP-DRAW

Septrianesa, Septrianesa - Personal Name;

Penilaian

0,0

dari 5
Penilaian anda saat ini :  

The lightning phenomenon is the event of the release of electric charge that occurs in the atmosphere, followed by bursts of light and electromagnetic wave radiation due to the effect of the transfer of charge that occurs between the earth and the air. Lightning strikes that can cause fatal damage result in the creation of lightning protection efforts to protect from the effects of lightning strikes. To create optimal lightning protection, knowledge of everything about lightning itself and also lightning protection is required. This study aims to evaluate the external protection system of lightning that is being worked on the Avtur Pulau Layang Storage Station by using SketchUp software and then create a series of lightning SPP equivalents to perform large voltage calculations when lightning strikes using ATP-Draw software. . The simulation results using SketchUp software showed that all thirteen buildings must have external SPP to reduce the impact of lightning strikes, where the need for water termination and down conductor for each building is different. Furthermore, for the simulation results using ATP-Draw software, it was obtained that the voltage that arises when lightning strikes hit the down conductor of office building buildings, avtur tanks and street lights in sequence is 22,729 kV, 23,506 kV and 22,798 kV. The voltage value that arises in the tank building avtur is greater than the office building and street lights.


Availability
Inventory Code Barcode Call Number Location Status
2107003101T51874T518742021Central Library (Referens)Available but not for loan - Not for Loan
Detail Information
Series Title
-
Call Number
T518742021
Publisher
Inderalaya : Prodi Teknik Elektro, Fakultas Teknik Universitas Sriwijaya., 2021
Collation
xxi, 60 hlm,: ilus.; 29 cm
Language
Indonesia
ISBN/ISSN
-
Classification
621.316 07
Content Type
Text
Media Type
-
Carrier Type
-
Edition
-
Subject(s)
Proteksi Petir Eksternal
Prodi Teknik Elektro
Alat-alat Kontrol Listrik
Specific Detail Info
-
Statement of Responsibility
MURZ
Other version/related

No other version available

File Attachment
  • EVALUASI SISTEM PROTEKSI PETIR EKSTERNAL DAN PERHITUNGAN TEGANGAN SAAT SAMBAR PETIR PADA STASIUN PENYIMPANAN AVTUR PULAU LAYANG BERBASIS SOFTWARE ATP-DRAW
Comments

You must be logged in to post a comment

The Sriwijaya University Library
  • Information
  • Services
  • Librarian
  • Member Area

About Us

As a complete Library Management System, SLiMS (Senayan Library Management System) has many features that will help libraries and librarians to do their job easily and quickly. Follow this link to show some features provided by SLiMS.

Search

start it by typing one or more keywords for title, author or subject

Keep SLiMS Alive Want to Contribute?

© 2025 — Senayan Developer Community

Powered by SLiMS
Select the topic you are interested in
  • Computer Science, Information & General Works
  • Philosophy & Psychology
  • Religion
  • Social Sciences
  • Language
  • Pure Science
  • Applied Sciences
  • Art & Recreation
  • Literature
  • History & Geography
Icons made by Freepik from www.flaticon.com
Advanced Search