Image of ANALISA RUGI-RUGI DAYA DAN JATUH TEGANGAN JARINGAN DISTRIBUSI TEGANGAN MENENGAH 20 KV PADA PENYULANG KENARI GARDU INDUK SEDUDUK PUTIH PALEMBANG

Skripsi

ANALISA RUGI-RUGI DAYA DAN JATUH TEGANGAN JARINGAN DISTRIBUSI TEGANGAN MENENGAH 20 KV PADA PENYULANG KENARI GARDU INDUK SEDUDUK PUTIH PALEMBANG

Rizki, Kgs M Rusdandi Amali - Personal Name;

Penilaian

0,0

dari 5
Penilaian anda saat ini :  

The need for electrical energy consumption is getting bigger every year due to population growth. This needs to be accompanied by the availability of sufficient electrical energy in order to meet consumer needs. One of the efforts made to meet these needs is the process of distributing electrical energy. In an electrical distribution system, the amount of supplied voltage and electrical power is not the same as that received. This is due to the occurrence of voltage drops and power losses in the distribution network which can be a loss for electricity producers and consumers because it can reduce the quality and optimization of the electrical energy. Voltage drop and power losses that occur can not be avoided, but can be reduced so that it is not too big. Therefore, a study was conducted to analyze the magnitude of the voltage drop and power losses that occurred in the Kenari feeder at Seduduk Putih Substation in Palembang. Based on the calculation results obtained from the Kenari feeder with a length of 8.376 km, the amount of power losses is 3,665.4505 Watt or 3.66 kW and the voltage is 87.2423 V with a percentage of 0.43%. The value of power losses and voltage drop is still within the standard limit set by PT. PLN (Persero) according to SPLN 1: 1995 regarding the standard limit for the voltage drop of the 20 kV distribution system, namely + 5% and -10% and with the smallest power loss values. Keywords: Distribution System, Drop Voltage, Power Losses


Availability
Inventory Code Barcode Call Number Location Status
2107003028T55523T555232021Central Library (Referens)Available but not for loan - Not for Loan
Detail Information
Series Title
-
Call Number
T555232021
Publisher
Inderalaya : Jurusan Teknik Elektro, Fakultas Teknik Universitas Sriwijaya., 2021
Collation
xvi, 50 hlm,: ilus.; 29 cm
Language
Indonesia
ISBN/ISSN
-
Classification
621.319 07
Content Type
Text
Media Type
-
Carrier Type
-
Edition
-
Subject(s)
Transmisi dan distribusi listrik
Jurusan Teknik Elektro
Specific Detail Info
-
Statement of Responsibility
MURZ
Other version/related

No other version available

File Attachment
  • ANALISA RUGI-RUGI DAYA DAN JATUH TEGANGAN JARINGAN DISTRIBUSI TEGANGAN MENENGAH 20 KV PADA PENYULANG KENARI GARDU INDUK SEDUDUK PUTIH PALEMBANG
Comments

You must be logged in to post a comment

The Sriwijaya University Library
  • Information
  • Services
  • Librarian
  • Member Area

About Us

As a complete Library Management System, SLiMS (Senayan Library Management System) has many features that will help libraries and librarians to do their job easily and quickly. Follow this link to show some features provided by SLiMS.

Search

start it by typing one or more keywords for title, author or subject

Keep SLiMS Alive Want to Contribute?

© 2025 — Senayan Developer Community

Powered by SLiMS
Select the topic you are interested in
  • Computer Science, Information & General Works
  • Philosophy & Psychology
  • Religion
  • Social Sciences
  • Language
  • Pure Science
  • Applied Sciences
  • Art & Recreation
  • Literature
  • History & Geography
Icons made by Freepik from www.flaticon.com
Advanced Search