Image of ANALISA KONFIGURASI DINDING GESER SEBAGAI DESAIN ALTERNATIF STUDI KASUS GEDUNG MAPOLDA PROVINSI SUMATERA SELATAN

Skripsi

ANALISA KONFIGURASI DINDING GESER SEBAGAI DESAIN ALTERNATIF STUDI KASUS GEDUNG MAPOLDA PROVINSI SUMATERA SELATAN

Gunawan, Jose Andre - Personal Name;

Penilaian

0,0

dari 5
Penilaian anda saat ini :  

Planning and designing earthquake resistant reinforced concrete high rise building in Indonesia are regulated in SNI 1726-2019 and SNI 2847-2019. Systems that are used to withstand earthquake forces in buildings with high levels are Moment Resistant Frame System (SRPM), Structural Wall System (SDS), and Dual System. A case study which is Mapolda Provinsi Sumatera Selatan Building have 8 stories that are planned and designed with Special Momen resistant Frame System (SRPMK) based on the location of the building which is in Palembang. There are 2 types of alternate design that has been analyzed using Dual System. The difference between 2 types of alternate design is on the location of the shear wall. First type of alternate design is using shear wall at the corner of the building. Second type of alternate design using shear wall on the side of the building. All type of the building analyzed using software SAP2000. There are some safety trouble during the analysis process of the existing building, therefore in planning the alternative design of the columns and beams the size is changed to suit the earthquake load that occurs in the building. Column dimensions were changed to 90 x 90 cm and 70 x 70 cm, and the beam dimensions were fixed but the beam reinforcement was added to strengthen the structure. The result of the performance analysis in story drift is alternative design type 1 have the smallest value compare to the existing and alternatif design type 2. In conclusion, alternate design modal using shear walls and enlarging column dimensions results is a safer design than the existing model.


Availability
Inventory Code Barcode Call Number Location Status
2107002941T51444T514442021Central Library (Referens)Available but not for loan - Not for Loan
Detail Information
Series Title
-
Call Number
T514442021
Publisher
Inderalaya : Prodi Teknik Sipil, Fakultas Teknik Universitas Sriwijaya., 2021
Collation
xvii, 86 hlm,: ilus.; 29 cm
Language
Indonesia
ISBN/ISSN
-
Classification
690.07
Content Type
Text
Media Type
-
Carrier Type
-
Edition
-
Subject(s)
Jurusan teknik sipil dan Perencanaan
Perencanaan, Analisa dan Teknik Bangunan
Specific Detail Info
-
Statement of Responsibility
MURZ
Other version/related

No other version available

File Attachment
  • ANALISA KONFIGURASI DINDING GESER SEBAGAI DESAIN ALTERNATIF STUDI KASUS GEDUNG MAPOLDA PROVINSI SUMATERA SELATAN
Comments

You must be logged in to post a comment

The Sriwijaya University Library
  • Information
  • Services
  • Librarian
  • Member Area

About Us

As a complete Library Management System, SLiMS (Senayan Library Management System) has many features that will help libraries and librarians to do their job easily and quickly. Follow this link to show some features provided by SLiMS.

Search

start it by typing one or more keywords for title, author or subject

Keep SLiMS Alive Want to Contribute?

© 2025 — Senayan Developer Community

Powered by SLiMS
Select the topic you are interested in
  • Computer Science, Information & General Works
  • Philosophy & Psychology
  • Religion
  • Social Sciences
  • Language
  • Pure Science
  • Applied Sciences
  • Art & Recreation
  • Literature
  • History & Geography
Icons made by Freepik from www.flaticon.com
Advanced Search