Image of PENENTUAN TITIK LOKASI GANGGUAN PADA RELE JARAK DENGAN METODE IMPEDANSI DI JARINGAN TRANSMISI PT. PLN (PERSERO) GI NEW JAKABARING - MARIANA

Skripsi

PENENTUAN TITIK LOKASI GANGGUAN PADA RELE JARAK DENGAN METODE IMPEDANSI DI JARINGAN TRANSMISI PT. PLN (PERSERO) GI NEW JAKABARING - MARIANA

Nurpadila, Muhammad Syaidar - Personal Name;

Penilaian

0,0

dari 5
Penilaian anda saat ini :  

In the electric power system, there are three parts, namely the generation system, transmission line system, and distribution channel system. The transmission line system can be useful for distributing electrical energy from the generating system to the electrical substation and also from an electric substation to another electrical substation, which will later be distributed to the distribution channel system. So it takes a good reliability and quality system on the transmission line in order to minimize the occurrence of a disturbance. On the transmission line there is a protection system in it, a protection system that is often used using a distance relay or distance relay. The relay has a type, one of which is an impedance relay. The distance relay can only indicate the fault area due to a short circuit, but this relay cannot determine the location of the fault specifically. Therefore, the results of the measurement of voltage, current, and impedance methods are used as a calculation for determining the location of the fault. In manual calculations using the impedance method, the value of each zone is zone 1, zone 2, and zone 3 on the secondary side, each with a value of 3.93987 ohms, 5.90981 ohms, and 26,16476 ohms. Then for the calculation of the location of the disturbance obtained a value of 16.66 km. then the percentage of error values in each zone is 0.1492%, 0.1323%, and 142,896%. Then for the percentage of the location of the disturbance obtained by 1.244% error value.


Availability
Inventory Code Barcode Call Number Location Status
2107002880T55521T555212021Central Library (Referens)Available but not for loan - Not for Loan
Detail Information
Series Title
-
Call Number
T555212021
Publisher
Inderalaya : Jurusan Teknik Elektro, Fakultas Teknik Universitas Sriwijaya., 2021
Collation
xvi, 55 hlm,: ilus.; 29 cm
Language
Indonesia
ISBN/ISSN
-
Classification
621.319 07
Content Type
Text
Media Type
-
Carrier Type
-
Edition
-
Subject(s)
Transmisi dan distribusi listrik
Jurusan Teknik Elektro
Specific Detail Info
-
Statement of Responsibility
MURZ
Other version/related

No other version available

File Attachment
  • PENENTUAN TITIK LOKASI GANGGUAN PADA RELE JARAK DENGAN METODE IMPEDANSI DI JARINGAN TRANSMISI PT. PLN (PERSERO) GI NEW JAKABARING - MARIANA
Comments

You must be logged in to post a comment

The Sriwijaya University Library
  • Information
  • Services
  • Librarian
  • Member Area

About Us

As a complete Library Management System, SLiMS (Senayan Library Management System) has many features that will help libraries and librarians to do their job easily and quickly. Follow this link to show some features provided by SLiMS.

Search

start it by typing one or more keywords for title, author or subject

Keep SLiMS Alive Want to Contribute?

© 2025 — Senayan Developer Community

Powered by SLiMS
Select the topic you are interested in
  • Computer Science, Information & General Works
  • Philosophy & Psychology
  • Religion
  • Social Sciences
  • Language
  • Pure Science
  • Applied Sciences
  • Art & Recreation
  • Literature
  • History & Geography
Icons made by Freepik from www.flaticon.com
Advanced Search