Image of KOORDINASI SETTING RELE ARUS LEBIH DAN RELE GANGGUAN TANAH PADA TRANSFORMATOR DAYA I 60 MVA DAN PENYULANG DISTRIBUSI 20 KV GARDU INDUK NEW JAKABARING

Skripsi

KOORDINASI SETTING RELE ARUS LEBIH DAN RELE GANGGUAN TANAH PADA TRANSFORMATOR DAYA I 60 MVA DAN PENYULANG DISTRIBUSI 20 KV GARDU INDUK NEW JAKABARING

Kalimatullah, Hauzaan - Personal Name;

Penilaian

0,0

dari 5
Penilaian anda saat ini :  

Abstract – In the Industrial 4.0 era, electricity are the main thing that support daily life activities. Therefore, In the distribution of electric power to the consumers should be good in quality and reliable against faults. In the distribution of electric power , it’s never free from Short Circuit faults. So, to localize the fault while protecting the main equipment in the distribution of protection, it needs relay coordination . The New Jakabaring Substation is equipped with protection relays, namely Over Current Relay (OCR) to anticipate two-phase short-circuit faults and Ground Fault Relay (GFR) to anticipate single-phase earth-short circuit faults. The study began with data collection in the observations field at the New Jakabaring Substation. Based on the calculations, it is known that the two-phase and single-phase short-circuit currents in the transformer consecutively are 1429.286 A and 37.886 A. In the Kutai feeder, the two-phase and single-phase short-circuit currents consecutively are 2108.550 A and 257.406 A, while in the Mataram feeder, two-phase and single-phase short￾circuit currents were obtained consecutively are 1498,833 A and 243,504 A. The values of the TMS OCR setting on the 150 kV transformer is 0.31 and the 20 kV side is 0.18. TMS OCR settings for the Kutai and Mataram feeders respectively are 0.08 and 0.07. The values of the TMS GFR on the 150 kV side of the transformer is 0.40 and the 20 kV side is 0.23. TMS GFR setting for both Kutai and Mataram feeders are same, They are 0.1


Availability
Inventory Code Barcode Call Number Location Status
2107002844T57634T576342021Central Library (Referens)Available but not for loan - Not for Loan
Detail Information
Series Title
-
Call Number
T576342021
Publisher
Inderalaya : Jurusan Teknik Elektro, Fakultas Teknik Universitas Sriwijaya., 2021
Collation
xv, 64 hlm,: ilus.; 29 cm
Language
Indonesia
ISBN/ISSN
-
Classification
621.314 07
Content Type
Text
Media Type
-
Carrier Type
-
Edition
-
Subject(s)
Jurusan Teknik Elektro
Transformator
Specific Detail Info
-
Statement of Responsibility
MURZ
Other version/related

No other version available

File Attachment
  • KOORDINASI SETTING RELE ARUS LEBIH DAN RELE GANGGUAN TANAH PADA TRANSFORMATOR DAYA I 60 MVA DAN PENYULANG DISTRIBUSI 20 KV GARDU INDUK NEW JAKABARING
Comments

You must be logged in to post a comment

The Sriwijaya University Library
  • Information
  • Services
  • Librarian
  • Member Area

About Us

As a complete Library Management System, SLiMS (Senayan Library Management System) has many features that will help libraries and librarians to do their job easily and quickly. Follow this link to show some features provided by SLiMS.

Search

start it by typing one or more keywords for title, author or subject

Keep SLiMS Alive Want to Contribute?

© 2025 — Senayan Developer Community

Powered by SLiMS
Select the topic you are interested in
  • Computer Science, Information & General Works
  • Philosophy & Psychology
  • Religion
  • Social Sciences
  • Language
  • Pure Science
  • Applied Sciences
  • Art & Recreation
  • Literature
  • History & Geography
Icons made by Freepik from www.flaticon.com
Advanced Search